Pumping machine operator. Job description of the operator of pumping units Job responsibilities of the operator of the pumping water intake

Job Responsibilities Maintenance of pumping units equipped with piston and centrifugal pumps with a total capacity of over 1000 to 3000 m3 / h of water, pulp and other non-viscous liquids, and pumping units for pumping oil, fuel oil, resin, etc. with a total capacity of pumps over 100 to 500 m3/h. Maintenance of pumps and pumping units in the field, at construction sites and industrial water intakes with a capacity of each pump or unit over 100 to 1000 m3/h of water and wellpoint installations with a pump capacity of over 100 to 600 m3/h each. Maintenance of vacuum pumping units for degassing coal mines with a total pump capacity of over 6,000 to 18,000 m3/h of methane-air mixture. Starting and stopping motors and pumps. Maintaining the set pressure of the pumped liquids (gas), monitoring the uninterrupted operation of pumps, motors and fittings of the serviced pipeline section. Maintenance of power and lighting electrical installations up to 1000 V. Performing simple electrical work at the substation. Regulation of the load of the electrical equipment of the site (substation). Identification and elimination of shortcomings in the operation of the serviced equipment of installations, including power and lighting electrical networks, electrical circuits of process equipment. Maintenance of technical accounting and reporting on the operation of pumping equipment. Performance current repair pumping equipment and participation in the average and overhauls his.

Must know: device and purpose of pumping equipment; installation of piston and centrifugal pumps for pumping liquids (gas); rules for the operation and repair of serviced equipment; air duct schemes for suction and discharge pipelines and control devices; design of clinkers and filters; fundamentals of electrical engineering, electrical engineering, hydraulics and mechanics; ways to troubleshoot equipment and eliminate accidents; appointment and use of instrumentation; rules and norms of labor protection, safety measures (when servicing electrical installations in the scope of qualification group II) and fire protection.

Starting and stopping motors and pumps. Maintaining the set pressure of the pumped liquids (gas), monitoring the uninterrupted operation of pumps, motors and fittings of the serviced pipeline section. Maintenance of power and lighting electrical installations up to 1000 V. Performing simple electrical work at the substation. Regulation of the load of the electrical equipment of the site (substation). Identification and elimination of shortcomings in the operation of the serviced equipment of installations, including power and lighting electrical networks, electrical circuits of process equipment. Maintenance of technical accounting and reporting on the operation of pumping equipment. Performance of current repairs of pumping equipment and participation in its medium and major repairs.

Job description of the driver of pumping units of the 4th category

BOOKS ON COMMUNICATIONS FOR FREE: Antennas Amateur radio equipmentCommunication lines, data transmissionMobile phonesTheory and practice of radio communication telemechanicsElectrician, electrician, electromechanicElectrical networks, overhead and cable linesElectric motorsElectrical equipmentElectric drivePower plants, substationsElectrical reference booksEnergy, power supply COLLECTIONS FOR FREE:To help the radio amateurRadioamator-the bestRadio Yearbook DIRECTORIES FOR FREE:Foreign microcircuits and transistorsMeasuring equipment.

Pumping unit operator: requirements etc

Maintenance of pumping stations (substations, installations) equipped with pumps and pipe pumps of various systems with a total capacity of over 3,000 to 10,000 cubic meters. m/h of water, pulp and other non-viscous liquids. Start regulation of the operating mode and stop of motors and pumps. Maintenance of pumps and pumping units in the field and on construction sites with a pump capacity of over 1000 to 3000 cubic meters.
m / h of water each and wellpoint and vacuum pumping units with a pump capacity of over 600 cubic meters. m/h each. Maintenance of pumps and pumping units of coal mines with a total pump capacity of over 18,000 cubic meters. m/h methane-air mixture. Control of ensuring the specified pressure of liquid, gas and pulp in the network of the serviced area. Maintenance of transformer substations under the guidance of a driver of higher qualification.

General provisions

Attention

I approve (organizational and legal (signature) (full name, position of the head, form, name or other official, organization, enterprise) authorized to approve the job description) "" 20 g. M.P. Job description engineer of pumping units of the 3rd category (name of organization, enterprise, etc.) This job description was developed and approved on the basis of employment contract with the driver of pumping units of the 3rd category in accordance with the Labor Code of the Russian Federation and other regulatory legal acts regulating labor relations. 1. General provisions 1.1. The driver of pumping units of the 3rd category belongs to the category of workers and is directly subordinate.


(name of position of immediate supervisor) 1.2.

Error 404 page does not exist

Engineer of pumping units (3rd category) (as amended by the Decree of the Ministry of Labor of the Russian Federation of July 19, 1993 N 140) Characteristics of work. Maintenance of pumping units equipped with piston and centrifugal pumps with a total capacity of over 1000 to 3000 cubic meters. m / h of water, pulp and other non-viscous liquids, and pumping units for pumping oil, fuel oil, resin, etc. with a total capacity of pumps over 100 to 500 cubic meters. m/h Maintenance of pumps and pumping units in the field, at construction sites and at industrial water intakes with a capacity of each pump or unit over 100 to 1000 cubic meters.
m / h of water and wellpoint installations with a pump capacity of over 100 to 600 cubic meters. m/h each. Maintenance of vacuum pumping units for degassing coal mines with a total pump capacity of over 6,000 to 18,000 cubic meters. m/h methane-air mixture.

Pumping unit operator

At the end of the duty: - check the technical condition of the operating equipment of the station and make appropriate entries in the log; - clean the engine room and equipment, as well as the area adjacent to the engine room; - close all hatches and covers that were used during the shift; - inform the shift worker about the state of the operating equipment that is in reserve and repair, about the shortcomings and malfunctions noticed during operation, about the measures taken to eliminate them and about the orders and instructions of the workshop administration; - pass the shift at the workplace with the execution of all entries in the work journal; - in case of absence (lateness) of the shift, report this to the administration of the workshop (shift supervisor), do not leave duty until the shift arrives. 4.

Instruction on labor protection for the driver of the fecal pumping station

Send to the trust "Rosvodokanalnaladka" Standard instructions for the order of Glavvodokanal. 5. To impose control over the execution of this Order on Glavvodokanal (comrade Elfimov). Minister F.V. Popov Standard instruction on labor protection for the driver of a sewer pumping station (approved by order

Ministry of Housing and Communal Services of the RSFSR dated May 14, 1984 No. 221) 1. Persons at least 18 years old who have been trained and tested on safety are allowed to the position of a sewer pumping station driver. The driver must undergo a medical examination upon admission to work and periodically once every 6 months.

2.
A Fascinating Journey Around the GlobeSpy StuffElectrician in the HouseEffective Tricks and Their Solutions MAGAZINES FREE OF CHARGE: Radioamator's NotebookHome ComputerHome PKKV MagazineKV and VHFKvantComputerraConstructorLeftyModeler-ConstructorM-HobbiesScience and LifeElectronics NewsNew Radio YearbookPopular MechanicsRadioDesignRadiatorRadio Television Electric Radio componentsRadio designerRadio amateurRadioworldRadio circuitRadiohobbyRepair and serviceElectronic equipment repairSelfservice centerPower machinesCircuit engineeringTechnology for young peopleChemistry and lifeEC&SElectricianElectronicsYoung technicianYoung technician for skillful handsI am an electricianA radio.

Important

Starting and stopping motors and pumps. 2.5. Maintaining the set pressure of the pumped liquids (gas), monitoring the uninterrupted operation of pumps, motors and fittings of the serviced pipeline section. 2.6. Maintenance of power and lighting electrical installations up to 1000 V. 2.7. Performing simple electrical work at the substation.


2.8.

Info

Regulation of the load of the electrical equipment of the site (substation). 2.9. Identification and elimination of shortcomings in the operation of the serviced equipment of installations, including power and lighting electrical networks, electrical circuits of process equipment. 2.10. Maintenance of technical accounting and reporting on the operation of pumping equipment.


2.11. Performance of current repairs of pumping equipment and participation in its medium and major repairs. 3. Rights The driver of pumping units of the 3rd category has the right to: 3.1.

Responsibilities of the pumping station operator

Unified Tariff and Qualification Handbook of Works and Professions of Workers (ETKS), 2017 Issue No. 1 ETKS Issue approved by the Decree of the USSR State Committee on Labor and Social Affairs and the Secretariat of the All-Union Central Council of Trade Unions dated January 31, 1985 N 31 / 3-30 (as amended by: Resolutions of the USSR State Labor Committee, Secretariat of the All-Union Central Council of Trade Unions of October 12, 1987 N 618 / 28-99, of December 18, 1989 N 416 / 25-35, of May 15, 1990 N 195 / 7-72, of June 22, 1990 N 248 / 10-28, Decrees of the USSR State Committee for Labor on December 18 .1990 N 451, Decrees of the Ministry of Labor of the Russian Federation of 12/24/1992 N 60, of 02/11/1993 N 23, of 07/19/1993 N 140, of 06/29/1995 N 36, of 06/01/1998 N 20, of 05/17/2001 N 40, Orders of the Ministry of Health and Social Development of the Russian Federation of July 31, 2007 N 497, of October 20, 2008 N 577, of April 17, 2009 N 199) Section ETKS “Professions of workers common to all industries National economy» § 208. Engineer of pumping units (2nd category) (as amended by the Decree of the Ministry of Labor of the Russian Federation of July 19, 1993 N 140) Description of work.

Job descriptionsHome workshopLife of remarkable physicistsFactory technologies at home - simple recipesTools and mechanisms for agricultureAudio artThe art of videoHistory of technology, technology, objects around usAnd then an inventor appearedLecture notes, cheat sheetsPersonal transport: land, water, airFor lovers of travel - tourist tipsMobile phonesModelingExperiments in physicsExperiments in chemistryRegulatory security documentation labor Basics of safe life (OBZhD) Fundamentals of first aid (OPMP) Occupational safety Parameters, analogs, marking of radio components Radio for beginners Secrets of repair Tips for radio amateurs Builder, home master Reference information Standard instructions for labor protection (TOI) Functional composition of imported TV Functional composition, remotes, chassis, equivalents of imported TVs

  • to request and receive the necessary materials and documents related to the issues of their activities and activities of employees subordinate to him;
  • interact with other services of the enterprise on production and other issues that are part of its functional duties;
  • get acquainted with the draft decisions of the company's management regarding the activities of the Division;
  • propose for consideration by the manager proposals for improving the work related to the duties provided for in this Job Description;
  • submit for consideration by the head of the proposal on the promotion of distinguished employees, the imposition of penalties on violators of production and labor discipline;
  • report to the manager on all identified violations and shortcomings in connection with the work performed.
  • IV.

The driver of pumping stations needs to know and strictly comply with the requirements for labor protection, fire safety, and industrial sanitation. 1.7. The driver of pumping stations must be able to use primary fire extinguishing equipment, know their location and monitor their serviceability. Fire extinguishers and a box of dry sand must be placed at the pumping station. In the premises of pumping stations, it is necessary to use only serviceable tools made of non-sparking material. 1.8. Storage of lubricants at pumping stations is allowed in a specified place in quantities not exceeding the daily requirement. Lubricants must be stored in special metal or plastic containers with tightly closed lids. It is not allowed to store flammable liquids in the pumping station. 1.9.

General provisions

REQUIREMENTS OF LABOR PROTECTION IN EMERGENCY SITUATIONS 4.1. In case of occurrence emergency it is necessary to act in accordance with the emergency response plan. 4.2. In the event of a fire at the pumping station, turn off the electricity, close the valves on the input and output lines of the pumps, call the fire brigade, report the incident to the management of the enterprise, and take measures to extinguish the fire.


4.3. If any malfunction is detected that disrupts the normal operation of the pump, it must be stopped. Make an entry about all the shortcomings noticed in the operation log of pumping units, and notify the management of the enterprise (or shift supervisor).
4.4. In the event of a sudden power outage, disconnect the pump motors from the mains, and then close the valves on the suction and pressure pipelines of the pumps. 4.5.

Job description of the driver of pumping units of the 4th category

Bandage the burnt surface with a sterile bandage and contact a medical institution. Notify the management of the shop.4.3. In case of electric shock, first of all release the victim from the action of electric current (disconnect the equipment from the mains).


Attention

If the victim has lost consciousness, but breathes, it is necessary to lay him down, unfasten the collar, give fresh air. If there is no breathing, the pulse is not felt, the victim should immediately do artificial respiration before the arrival of a doctor.


5. SAFETY REQUIREMENTS AFTER WORK COMPLETE 5.1. At the end of his duty, the driver is obliged to check the condition of pumps, electric motors and auxiliary equipment. Record in the log of acceptance - delivery of the shift all the work performed by him to eliminate defects found during the operation of the equipment, as well as defects that have not been eliminated.5.2.

Pumping unit operator: requirements etc

GENERAL SAFETY REQUIREMENTS 1.1. Persons at least 18 years of age who have passed a medical examination, have passed an introductory briefing, fire safety briefing, primary briefing at the workplace, training in safe labor methods and techniques and passed an exam are allowed to work independently as a pumping station operator. The employee must undergo: - repeated safety briefing at the workplace (quarterly), - unscheduled briefing: in case of changes in technological process, replacement or modernization of devices and tools, changes in working conditions and organization, the emergence of new factors affecting labor safety, in case of violations of labor protection instructions, interruptions in work for more than 60 calendar days, 1.3.

Labor protection instruction for pumping station operators

Tidy up your workspace and get dressed. Protective clothing and footwear should be stored separately from personal clothing. 5.3. Take a warm shower, wash your face and hands thoroughly warm water with soap.

Info

See other articles in the Occupational Safety and Health section. Read and write helpful comments on this article. We recommend downloading from our Free Technical Library: magazines Elektor Electronics 2015 (archive for the year) magazines Home computer 2007 (archive for the year) the book Maintenance and repair of large vertical electric motors.


Sokolov R.I., 1988 book Radio amateurs - to the rural club. Vasiliev V.A., 1983 article Trolleybus driver.

Instructions for the driver of the pumping station

Order of the Ministry of Housing and Communal Services of the RSFSR dated May 14, 1984 No. 221 “On Approval and Enactment of Standard Labor Protection Instructions” I order: household enterprises Standard instructions for labor protection for drivers of water supply and sewer pumping stations, operators of a chlorination plant, mechanics of emergency repair work of sewer networks.
2. Heads of water supply and sewerage enterprises in relation to local conditions, on the basis of approved Model Instructions, develop instructions on labor protection for workers of the above professions. 3. The main computing center (comrade Fursik) to publish in the III quarter.
this year the specified Instructions with a circulation of 350 copies. 4.
At the end of the duty: - check the technical condition of the operating equipment of the station and make appropriate entries in the log; - clean the engine room and equipment, as well as the area adjacent to the engine room; - close all hatches and covers that were used during the shift; - inform the shift worker about the state of the operating equipment that is in reserve and repair, about the shortcomings and malfunctions noticed during operation, about the measures taken to eliminate them and about the orders and instructions of the workshop administration; - pass the shift at the workplace with the execution of all entries in the work journal; - in case of absence (lateness) of the shift, report this to the administration of the workshop (shift supervisor), do not leave duty until the shift arrives. 4.
At the end of the duty: - check the technical condition of the operating equipment of the station and make appropriate entries in the log; - clean the engine room and equipment, as well as the area adjacent to the engine room; - inform the shift worker about the state of the operating equipment that is in reserve and repair, about the shortcomings and malfunctions noticed during operation, about the measures taken to eliminate them and about the orders and instructions of the workshop administration; - pass the shift at the workplace with the execution of all entries in the work journal; - in case of absence (lateness) of the shift, report this to the administration of the workshop (shift supervisor), do not leave duty until the shift arrives. 4.

Instructions for the driver of a pumping station in housing and communal services

In case of an accident, it is necessary to provide the victim with first aid, if necessary, call an ambulance, inform your immediate supervisor and keep the situation at the workplace unchanged until the investigation, if it does not pose a threat to employees and does not lead to an accident. 5. REQUIREMENTS OF LABOR SAFETY AFTER THE END OF WORK 5.1. Hand over duty to a shift driver with an entry in the operation log of pumping units about all the shortcomings, malfunctions, instructions, orders of the management.

It is not allowed to leave the workplace before the arrival of the shift. In case of non-arrival of the shift driver, notify the management or the shift supervisor.

5.2. Tidy up your workspace and get dressed. Protective clothing and footwear should be stored separately from personal clothing. 5.3.
The employee is obliged to: - use for the intended purpose and take care of the issued personal protective equipment. - be able to provide first (first aid) assistance to the victim in an accident; first aid, primary fire extinguishing equipment, main and emergency exits, escape routes in case of fire or accident. - perform only assigned work, do not transfer it to others without the permission of the foreman or head of the shop, - keep the workplace clean and tidy, do not clutter it with parts, blanks , metal waste, garbage, etc. - during work, be attentive, not be distracted and not distract others, do not allow persons who are not related to work to the workplace. 1.5. The pumping station operator must know and follow the rules of personal hygiene.

For local lighting or in the absence of electricity, the pumping station operator should use a portable rechargeable lamp in an explosion-proof design with a voltage of not more than 12 V, which is turned on and off outside the pumping station. It is not allowed to use open flame sources for lighting.

1.10. Smoking and eating is allowed only in places specially designated for this purpose. 2. Labor protection requirements before starting work 2.1. Put on the overalls and special footwear provided for by the relevant standards. Overalls must be buttoned up. 2.2. Familiarize yourself with the entries in the operation log of pumping units. 2.3.